About the authors

« Empty Part Number for Content Center Library components | Main | Environment variable "InvCM_ForceConvertToGeneric" to convert legacy colors to generic type in Inventor 2013 »

01/09/2013

Comments

Feed You can follow this conversation by subscribing to the comment feed for this post.

Trivia for you: what are the "units" of the Margin for Reference/Hidden Line Calculation. ie: explain, why it may start out 1?

Why will it most times start out less than 1?
Why must you increase the margin greater than 1 to see most or all of the reference part(s)?

The unit of the margin is cm.

You can approximately calculate the default value with the formula below.

Margin (in cm) = 0.1 x View Scale x Bounding box assembly (smallest side) in cm

I hope it helps.

Regards.
Ale

The comments to this entry are closed.

RSS Feed

  • Subscribe

April 2014

Sun Mon Tue Wed Thu Fri Sat
    1 2 3 4 5
6 7 8 9 10 11 12
13 14 15 16 17 18 19
20 21 22 23 24 25 26
27 28 29 30      

Self-Service Kiosk

Did not find what you were looking for?
Give the Inventor Self-Service Kiosk a try and hit the Start button
Note: the kiosk momentarily only works with Internet Explorer
kiosk